LMR400 Times coaxial cable

Quick Reference

Impedance 50 Ohm
Frequency Range DC – 6 GHz
Outer Diameter .400 INCH
Velocity Factor 85%
Capacitance 23.9 pF/ft
Max Voltage 600 VRMS
Dielectric Foamed PE
Shield Aluminum foil + tinned copper braid
Jacket PE
Min Bend Radius 2.0 in (50mm)
Weight 5.0 lb/100ft
Temp Range -40°C to +85°C
Center Conductor Bare copper clad aluminum, 2.74mm

LMR400 Times Coaxial Cable

50 Ohm • DC – 6 GHz

LMR-400 is the industry-standard low-loss 50-ohm coaxial cable from Times Microwave with a 0.400" outer diameter, offering less than half the signal loss of RG-8 at 2.4 GHz. The go-to cable for base station feedlines, cellular repeater installations, antenna runs from 50 to 200 feet, and any fixed installation requiring reliable broadband performance.

LMR400 Times Attenuation

Signal loss in dB per 100 ft at standard RF frequencies.

Frequency Loss / 100 ft Loss / ft 6 ft 25 ft 50 ft 100 ft
100 MHz 1.5 dB 0.015 dB 0.09 dB 0.38 dB 0.75 dB 1.5 dB
450 MHz 3.3 dB 0.033 dB 0.2 dB 0.83 dB 1.65 dB 3.3 dB
900 MHz 4.7 dB 0.047 dB 0.28 dB 1.18 dB 2.35 dB 4.7 dB
1.8 GHz 6.8 dB 0.068 dB 0.41 dB 1.7 dB 3.4 dB 6.8 dB
2.4 GHz 7.9 dB 0.079 dB 0.47 dB 1.98 dB 3.95 dB 7.9 dB
5.8 GHz 13 dB 0.13 dB 0.78 dB 3.25 dB 6.5 dB 13 dB

LMR400 Times Power Handling

Approximate maximum continuous power (CW) at 25°C ambient.

Frequency Max Power (W)
100 MHz 500 W
450 MHz 220 W
900 MHz 150 W
1.8 GHz 100 W
2.4 GHz 85 W
5.8 GHz 50 W

Construction & Materials

Center Conductor

Bare copper clad aluminum, 2.74mm

The center conductor carries the RF signal. Material and diameter affect DC resistance, skin effect losses, and overall attenuation.

Dielectric

Foamed PE

The dielectric insulator separates the center conductor from the shield. PTFE dielectrics offer superior temperature stability and lower loss versus polyethylene.

Shield

Aluminum foil + tinned copper braid

The outer conductor provides the return path and shields the signal from external interference. More braid coverage means better EMI rejection.

Jacket

PE

The outer jacket protects the cable from physical damage, UV, chemicals, and moisture. PTFE and FEP jackets handle higher temperatures than PVC.

Velocity Factor

85% (c)

How fast the signal travels relative to the speed of light in vacuum. Higher velocity factor means shorter electrical wavelength per foot — important for phased array and delay-matched applications.

Max Voltage

600 VRMS

The maximum continuous operating voltage. Exceeding this can cause dielectric breakdown. Relevant for high-power transmitters and pulse applications.

Available LMR400 Times Assemblies

Choose a connector combination to see pricing and order. All assemblies are hand-built and ship free within the USA.

73 more configurations available on the LMR400 Times page.

Frequently Asked Questions

What is the impedance of LMR400 Times?

LMR400 Times is a 50 Ohm coaxial cable. All standard RF systems (antennas, transceivers, test equipment) use 50-ohm impedance, so LMR400 Times connects directly without any matching network.

What frequency range does LMR400 Times support?

LMR400 Times is rated DC – 6 GHz. At higher frequencies, the attenuation per foot increases, so actual usable range depends on acceptable signal loss for your application.

How much signal loss does LMR400 Times have?

LMR400 Times has 1.5 dB of attenuation per 100 ft at 100 MHz, rising to 13 dB per 100 ft at 5.8 GHz. Use the attenuation table above to calculate loss for any specific length and frequency.

Are CoaxRF LMR400 Times cable assemblies made in the USA?

Yes. Every LMR400 Times assembly is hand-terminated and continuity tested at our US facility. We build each cable to order — nothing is pre-made or drop-shipped from overseas.

Can I order a custom length of LMR400 Times?

Yes. In addition to our standard lengths (1, 6, 25, 50, 100 ft and longer), we accept custom-length orders through the Cable Builder. Custom assemblies ship within 1–2 business days.