RG316DS coaxial cable

Quick Reference

Impedance 50 Ohm
Frequency Range DC – 6 GHz
Outer Diameter .1 INCH
Velocity Factor 70%
Capacitance 29.0 pF/ft
Max Voltage 1200 VRMS
Dielectric Solid PTFE
Shield Double silver-plated copper braid (95%)
Jacket FEP
Min Bend Radius 0.5 in (13mm)
Weight 1.2 lb/100ft
Temp Range -55°C to +200°C
Center Conductor Silver-plated copper clad steel, 7×0.17mm

RG316DS Coaxial Cable

50 Ohm • DC – 6 GHz

RG-316DS is a double-shielded version of RG-316, featuring two braid layers over the PTFE dielectric for superior EMI isolation. This construction reduces signal leakage and interference pickup, making it essential in sensitive receiver chains, spectrum analyzers, and high-density RF wiring where crosstalk must be minimized.

RG316DS Attenuation

Signal loss in dB per 100 ft at standard RF frequencies.

Frequency Loss / 100 ft Loss / ft 6 ft 25 ft 50 ft 100 ft
100 MHz 5.3 dB 0.053 dB 0.32 dB 1.33 dB 2.65 dB 5.3 dB
450 MHz 12 dB 0.12 dB 0.72 dB 3 dB 6 dB 12 dB
900 MHz 17.5 dB 0.175 dB 1.05 dB 4.38 dB 8.75 dB 17.5 dB
1.8 GHz 26 dB 0.26 dB 1.56 dB 6.5 dB 13 dB 26 dB
2.4 GHz 30.5 dB 0.305 dB 1.83 dB 7.63 dB 15.25 dB 30.5 dB
5.8 GHz 52 dB 0.52 dB 3.12 dB 13 dB 26 dB 52 dB

RG316DS Power Handling

Approximate maximum continuous power (CW) at 25°C ambient.

Frequency Max Power (W)
100 MHz 50 W
450 MHz 22 W
900 MHz 15 W
1.8 GHz 10 W
2.4 GHz 8 W
5.8 GHz 5 W

Construction & Materials

Center Conductor

Silver-plated copper clad steel, 7×0.17mm

The center conductor carries the RF signal. Material and diameter affect DC resistance, skin effect losses, and overall attenuation.

Dielectric

Solid PTFE

The dielectric insulator separates the center conductor from the shield. PTFE dielectrics offer superior temperature stability and lower loss versus polyethylene.

Shield

Double silver-plated copper braid (95%)

The outer conductor provides the return path and shields the signal from external interference. More braid coverage means better EMI rejection.

Jacket

FEP

The outer jacket protects the cable from physical damage, UV, chemicals, and moisture. PTFE and FEP jackets handle higher temperatures than PVC.

Velocity Factor

70% (c)

How fast the signal travels relative to the speed of light in vacuum. Higher velocity factor means shorter electrical wavelength per foot — important for phased array and delay-matched applications.

Max Voltage

1200 VRMS

The maximum continuous operating voltage. Exceeding this can cause dielectric breakdown. Relevant for high-power transmitters and pulse applications.

Available RG316DS Assemblies

Choose a connector combination to see pricing and order. All assemblies are hand-built and ship free within the USA.

135 more configurations available on the RG316DS page.

Frequently Asked Questions

What is the impedance of RG316DS?

RG316DS is a 50 Ohm coaxial cable. All standard RF systems (antennas, transceivers, test equipment) use 50-ohm impedance, so RG316DS connects directly without any matching network.

What frequency range does RG316DS support?

RG316DS is rated DC – 6 GHz. At higher frequencies, the attenuation per foot increases, so actual usable range depends on acceptable signal loss for your application.

How much signal loss does RG316DS have?

RG316DS has 5.3 dB of attenuation per 100 ft at 100 MHz, rising to 52 dB per 100 ft at 5.8 GHz. Use the attenuation table above to calculate loss for any specific length and frequency.

Are CoaxRF RG316DS cable assemblies made in the USA?

Yes. Every RG316DS assembly is hand-terminated and continuity tested at our US facility. We build each cable to order — nothing is pre-made or drop-shipped from overseas.

Can I order a custom length of RG316DS?

Yes. In addition to our standard lengths (1, 6, 25, 50, 100 ft and longer), we accept custom-length orders through the Cable Builder. Custom assemblies ship within 1–2 business days.